Alternative Health & Beauty Store Order Tracking |  Log In | Cart Contents | Checkout  
Health & Beauty Health Supplements Special Supplements Musics & e-books Best Sellers
  Categories
  Cards We Accept
Cards We Accept
Home » Acupuncture » Acupunctoscope »
Electronic Acupunctoscope - WQ10C2/D1 List Price: $179.00 USD
Our Price: $159.50 USD
You Save: 10% or $19.50 USD
US & Canada Shipping cost: $21.50 USD

wq10d2.jpg
title.jpg
WQ-10C2
WQ-10D1
The Multiple Electronic Acupunctoscope (MEA), Model WQ-10C2 is an instrument used both as a detector of acupuncture points and as an electrical stimulator for acupuncture therapy and anesthesia. The WQ-10D1 model is a newly modified unit from the older WQ-10 series acupunctoscope, featuring a CA(constant amplitude)-AM(amplitude modulation) selecting switch to allow it to discharge six different combinations of wave patterns.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Electronic Acupunctoscope Feature:
features.jpg
WQ-10C2
Multiplier Kx1 / Frequency f(c/s) 0~100 / Width T(μs) 250 ~ 300
Multiplier Kx10 / Frequency f(c/s) 0~1000 / Width T(μs) 50 ~ 60
I. The adjustment of the stimulating wave forms and frequencies. They are controlled by following knobs and switch:
F1=fixed frequencies
F2=variable frequencies
K=multiplier
There are two positions on switch k, “x1” and “x0.1”. The frequency of output impulse, F=Kfi, can be adjusted within two different ranges, (0~100Hz and 0~10Hz). There are 3 different forms of combinations by using f1 and f2:
1. When f2 is at 0, by adjusting f1, a continuous wave is obtained.
2. When f2 is at 0, by adjusting f2, an intermittent wave is obtained.
3. By adjusting f1 and f2, but keep f1 < f2 , a composite wave of alternating frequencies f1 and f2 is obtained
II. Acupuncture therapy and anesthesia
1. Set “Intensity” knob to zero and “E-E or APD” switch to “1.2.3”, set “Hi-Lo” switch to “Hi” or “Lo” position as required. Intensity of “Lo” position is 1/3 of “Hi”.
2. Plug output leads into 1.2.3 sockets, then fasten their clips to the handles of the needles.
3. Set the desirable waveforms and frequencies with knobs f1, f2 and K.
4. Turn “on” main switch
5. Adjust intensity to appropriate degree
III. Therapy with Electric, Excitatory(E-E) and 'skin sure' face acupuncture point stimulation:
1. Use output leads with banana plugs. Connect the bananas plugs with probes provided with cup shaped electrodes at terminal ends. Fill the cup with absorbent cotton soaked with salt solution. Fix the cup electrode onto the acupuncture points or the other selected parts of the skin. Set “Hi-Lo” switch to “Hi” position.
2. In case of weak stimulation follow the same steps described in II. Plug output leads into 1.2.3 sockets.
3. For strong stimulation, the output will be taken from the “E-E or APD” socket, which is specially designed for this purpose. Set”E-E or APD” switch to “E-E1+2+3” position and intensity is regulated by 1.2.3 channels together.
IV. Detection of “Meridian Sensitivity”
Subjects are found to be more sensitive to acupuncture. A particular sensation traveling along the pathways of meridians is demonstrated when the “Ching-Hsueh” (at the terminal parts of four limbs) is stimulated with electric impulse of appropriate intensity. This sensation is termed the meridian sensation. In most sensitive subjects the meridian sensation can travel along the pathway of the meridian and sometimes even extends to the neighboring meridian . The meridian sensitivity varies with different subjects, while the intensity of the electric excitation required to produce this particular sensation varies from person to person. Subjects who show more “meridian sensitivity” always react to acupuncture therapy and anesthesia with better results than those who are insensitive to it.
WQ-10D1
Frequency f(c/s) 0~100 / Width T(μs) 250 ~ 400
I. The adjustment of the stimulating wave forms and frequencies. They are controlled by following knobs and switch:
F1=fixed frequencies
F2=variable frequencies
CA (constant amplitude)-AM(amplitude modulation) selecting switch.
CA (constant amplitude)-AM(amplitude modulation) selecting switch.
There are six different forms of combinations by using f1 and f2 CA-AM
1. When f2 is at 0, by adjusting f1, a continuous (CA) or rise-fall(AM) wave is obtained.
2. When f1 is at 0, by adjusting f2, an intermittent (CA) or saw tooth (AM) wave is obtained.
3. By adjusting f1 and f2, but keep f1
Electronic Acupunctoscope - WQ-10C2 / WQ-10D1
II. Acupuncture therapy and anesthesia
1. Set “Intensity” knob to zero and “E-E or APD” switch to “1.2.3”, set “Hi-Lo” switch to “Hi” or “Lo” position as required. Intensity of “Lo” position is 1/3 of “Hi”.
2. Plug output leads into 1.2.3 sockets, then fasten their clips to the handles of the needles.
3. Set the desirable waveforms and frequencies with knobs f1, f2 and K.
4. Turn “on” main switch
5. Adjust intensity to appropriate degree
III. Therapy with Electric, Excitatory(E-E) and skin sure face acupuncture point stimulation:
1. Use output leads with banana plugs. Connect the bananas plugs with probes provided with cup shaped electrodes at terminal ends. Fill the cup with absorbent cotton soaked with salt solution. Fix the cup electrode onto the acupuncture points or the other selected parts of the skin. Set “Hi-Lo” switch to “Hi” position.
2. In case of weak stimulation follow the same steps described in II. Plug output leads into 1.2.3 sockets.
3. for strong stimulation, the output will be taken from the “E-E or APD” socket, which is specially designed for this purpose. Set”E-E or APD” switch to “E-E1+2+3” position and intensity is regulated by 1.2.3 channels together.
Electronic Acupunctoscope - WQ-10C2 / WQ-10D1 Electronic Acupunctoscope - WQ-10C2 / WQ-10D1
1. Power Supply ON/OFF
2. Knob Sensitivity of Adjustment
3. Fixed Frequency
4. Variable Frequency Switch, Stimulating Output Socket
5. CA / AM Selecting Switch for WQ-10D1, x0.1 / x1 Selecting Switch for WQ-10C2
6. Frequency Indicator Green LCD Light
7. Adjustable Intensity
8. E - E or APD Socket
9. 10.11. Stimulating Output Socket
12.Inject for AC Adapter ( Adaper not included )
13.Electric Excitatory or Acupuncture Points, Detection Selecting Switch
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1. Multiple usages:
A. The section used for acupuncture point detection can also be used for locating the auriculo-acupuncture points, meridian points, and band of (?) zone of acupuncture points.
B. The section used for stimulation can also be used for acupuncture therapy, skin surface acupuncture point stimulation, electrical Ti-Needle, acupuncture anesthesia, therapy by electric excitation, and measuring the sensitivity of meridian.
Both A and B sections maybe used at the same time.

2. Multiple transmit messages:
The instrument can transmit three waveforms of impulse series. Their frequency varies from 0-100 C/S, with several adjustment combinations. By varying the combinations of these differing massage types, a large number of stimulating conditions may be derived in order to prevent repetitious overuse, enhancing therapeutical efficiency.

3. High intensity of output: divided into "High" and "Low" two ranges, smooth adjustment, high stability and low power consumption.

4. Detecting acupuncture points with accuracy and without producing pain sensation. After the location of point, stimulating pulses can also provide therapy from the detecting probe. .

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Electronic Acupunctoscope - WQ-10C2 Electronic Acupunctoscope - WQ-10D1
WQ-10C2
WQ-10D1
1. Output leads with clips ( 3 sets)
2. Output leads with banana plugs ( 1 set)
3. Ground pole (1 pc.)
4. Cup-shaped electrode for electric excitation (1 pcs.)
5. Probe attachment with a cylindrical electrode for detection of "meridian sensitivity" at one end and a conical head for acupuncture points detection at the other ( 1 pc.)
6. Monitoring loudspeaker (1 pc.)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Electronic Acupunctoscope Technical Description:
Model name
WQ-10C2
WQ-10D1
Power source
9V battery, type PP3,6F22 or its equivalent
9V battery, type PP3,6F22 or its equivalent
Output
3 channels can be in succession connected into one channel as an electric excitation0output
3 channels can be in succession connected into one channel as an electric excitation0output
Multiplier
x1
x10
-----
Frequency ( c/s )
0 ~ 100
0 ~ 1000
0 ~100
Pluse Width ( s )
0.25 ~ 0.4
0.4 ~ 0.6
0.25 ~ 0.4
Width Type
continuous, intermittent and dense disperse
continuous, intermittent and dense disperse
Dimensions
145 x 100 x 70 mm
145 x 100 x 70 mm

Available Options:
Model:
Current no reviews for this product Write a new review >>
  Customers also bought
  Advance Search
 
Advanced Search
  Shopping Cart more
0 items
  Your Account
Your Email Address
Your Password
  Best Sellers
01.Electronic Acupunctoscope - WQ6F
02.Acupuncture Stimulator - KWD-808
03.Electronic Acupunctoscope - WQ10C2/D1
04.Electronic Acupunctoscope - AWQ104E/L
05.Acupunctoscope G series
  Information
Ordering Info
About Us
Pricing Policy
Privacy
Return Policy
What is ISO13488
Shipping Info
FAQ
Herbal Safety Guidelines
INFRARED JADE MATTRESS CONTROL PANEL
HOW TO USE THE SILVER MATTRESS
Links
Contact Us
Site Map
Vendor
All Rightes Reserved
Copyright © 2006-2008 3DHealthStore - All rights reserved | Conditions of use | Privacy Policy
*** All prices in USD (U.S. dollars) ***